| Flaming Gorge | 5-Oct-10 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.21 | 5602.79 | 422.42 | 26 | 1010 | 0 | 0 | 1010 | N/A |
| 200 | 6025.27 | 5602.79 | 422.48 | 26 | 1008 | 0 | 0 | 1008 | -2 |
| 300 | 6025.27 | 5602.79 | 422.48 | 26 | 1010 | 0 | 0 | 1010 | 2 |
| 400 | 6025.23 | 5602.79 | 422.44 | 26 | 994 | 0 | 0 | 994 | -16 |
| 500 | 6025.23 | 5602.79 | 422.44 | 26 | 1002 | 0 | 0 | 1002 | 8 |
| 600 | 6025.25 | 5602.85 | 422.40 | 27 | 1320 | 0 | 0 | 1320 | 318 |
| 700 | 6025.23 | 5603.46 | 421.77 | 45 | 1550 | 0 | 0 | 1550 | 230 |
| 800 | 6025.23 | 5603.47 | 421.76 | 46 | 1618 | 0 | 0 | 1618 | 68 |
| 900 | 6025.23 | 5603.50 | 421.73 | 47 | 1612 | 0 | 0 | 1612 | -6 |
| 1000 | 6025.23 | 5603.50 | 421.73 | 47 | 1614 | 0 | 0 | 1614 | 2 |
| 1100 | 6025.23 | 5603.50 | 421.73 | 47 | 1604 | 0 | 0 | 1604 | -10 |
| 1200 | 6025.21 | 5603.51 | 421.70 | 47 | 1604 | 0 | 0 | 1604 | 0 |
| 1300 | 6025.23 | 5603.51 | 421.72 | 47 | 1600 | 0 | 0 | 1600 | -4 |
| 1400 | 6025.23 | 5603.50 | 421.73 | 47 | 1612 | 0 | 0 | 1612 | 12 |
| 1500 | 6025.21 | 5603.50 | 421.71 | 47 | 1624 | 0 | 0 | 1624 | 12 |
| 1600 | 6025.21 | 5603.50 | 421.71 | 47 | 1618 | 0 | 0 | 1618 | -6 |
| 1700 | 6025.23 | 5603.50 | 421.73 | 47 | 1606 | 0 | 0 | 1606 | -12 |
| 1800 | 6025.23 | 5603.50 | 421.73 | 47 | 1618 | 0 | 0 | 1618 | 12 |
| 1900 | 6025.21 | 5603.50 | 421.71 | 47 | 1618 | 0 | 0 | 1618 | 0 |
| 2000 | 6025.21 | 5603.50 | 421.71 | 47 | 1602 | 0 | 0 | 1602 | -16 |
| 2100 | 6025.21 | 5603.47 | 421.74 | 46 | 1592 | 0 | 0 | 1592 | -10 |
| 2200 | 6025.21 | 5603.42 | 421.79 | 45 | 1268 | 0 | 0 | 1268 | -324 |
| 2300 | 6025.19 | 5602.79 | 422.40 | 27 | 1000 | 0 | 0 | 1000 | -268 |
| 2400 | 6025.19 | 5602.79 | 422.40 | 26 | 1010 | 0 | 0 | 1010 | 10 |
| Average | 6025.22 | 5603.26 | 421.97 | 40 | 1405 | 0 | 0 | 1405 | |
| Total | 956 | 33714 | 0 | 0 | 33714 | ||||
| Flaming Gorge | 5-Oct-11 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.19 | 5602.79 | 422.40 | 26 | 996 | 0 | 0 | 996 | -14 |
| 200 | 6025.21 | 5602.79 | 422.42 | 26 | 1016 | 0 | 0 | 1016 | 20 |
| 300 | 6025.19 | 5602.79 | 422.40 | 26 | 1008 | 0 | 0 | 1008 | -8 |
| 400 | 6025.19 | 5602.79 | 422.40 | 26 | 996 | 0 | 0 | 996 | -12 |
| 500 | 6025.21 | 5602.79 | 422.42 | 26 | 998 | 0 | 0 | 998 | 2 |
| 600 | 6025.19 | 5602.85 | 422.34 | 27 | 1312 | 0 | 0 | 1312 | 314 |
| 700 | 6025.19 | 5603.46 | 421.73 | 45 | 1564 | 0 | 0 | 1564 | 252 |
| 800 | 6025.21 | 5603.47 | 421.74 | 46 | 1630 | 0 | 0 | 1630 | 66 |
| 900 | 6025.21 | 5603.50 | 421.71 | 47 | 1606 | 0 | 0 | 1606 | -24 |
| 1000 | 6025.19 | 5603.50 | 421.69 | 47 | 1624 | 0 | 0 | 1624 | 18 |
| 1100 | 6025.21 | 5603.49 | 421.72 | 47 | 1630 | 0 | 0 | 1630 | 6 |
| 1200 | 6025.21 | 5603.50 | 421.71 | 47 | 1600 | 0 | 0 | 1600 | -30 |
| 1300 | 6025.21 | 5603.50 | 421.71 | 47 | 1606 | 0 | 0 | 1606 | 6 |
| 1400 | 6025.19 | 5603.50 | 421.69 | 47 | 1628 | 0 | 0 | 1628 | 22 |
| 1500 | 6025.19 | 5603.50 | 421.69 | 47 | 1606 | 0 | 0 | 1606 | -22 |
| 1600 | 6025.21 | 5603.50 | 421.71 | 47 | 1618 | 0 | 0 | 1618 | 12 |
| 1700 | 6025.21 | 5603.50 | 421.71 | 47 | 1618 | 0 | 0 | 1618 | 0 |
| 1800 | 6025.17 | 5603.50 | 421.67 | 47 | 1616 | 0 | 0 | 1616 | -2 |
| 1900 | 6025.17 | 5603.50 | 421.67 | 47 | 1624 | 0 | 0 | 1624 | 8 |
| 2000 | 6025.19 | 5603.50 | 421.69 | 47 | 1606 | 0 | 0 | 1606 | -18 |
| 2100 | 6025.19 | 5603.47 | 421.72 | 46 | 1568 | 0 | 0 | 1568 | -38 |
| 2200 | 6025.17 | 5603.41 | 421.76 | 45 | 1280 | 0 | 0 | 1280 | -288 |
| 2300 | 6025.17 | 5602.79 | 422.38 | 27 | 1010 | 0 | 0 | 1010 | -270 |
| 2400 | 6025.19 | 5602.79 | 422.40 | 26 | 1008 | 0 | 0 | 1008 | -2 |
| Average | 6025.19 | 5603.26 | 421.94 | 40 | 1407 | 0 | 0 | 1407 | |
| Total | 956 | 33768 | 0 | 0 | 33768 | ||||
| Flaming Gorge | 5-Oct-12 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.19 | 5602.79 | 422.40 | 26 | 1010 | 0 | 0 | 1010 | 2 |
| 200 | 6025.17 | 5602.79 | 422.38 | 26 | 998 | 0 | 0 | 998 | -12 |
| 300 | 6025.19 | 5602.79 | 422.40 | 26 | 1014 | 0 | 0 | 1014 | 16 |
| 400 | 6025.19 | 5602.79 | 422.40 | 26 | 1000 | 0 | 0 | 1000 | -14 |
| 500 | 6025.19 | 5602.79 | 422.40 | 26 | 1006 | 0 | 0 | 1006 | 6 |
| 600 | 6025.19 | 5602.84 | 422.35 | 27 | 1280 | 0 | 0 | 1280 | 274 |
| 700 | 6025.19 | 5603.46 | 421.73 | 45 | 1638 | 0 | 0 | 1638 | 358 |
| 800 | 6025.19 | 5603.46 | 421.73 | 46 | 1646 | 0 | 0 | 1646 | 8 |
| 900 | 6025.17 | 5603.50 | 421.67 | 47 | 1600 | 0 | 0 | 1600 | -46 |
| 1000 | 6025.19 | 5603.50 | 421.69 | 47 | 1622 | 0 | 0 | 1622 | 22 |
| 1100 | 6025.19 | 5603.50 | 421.69 | 47 | 1608 | 0 | 0 | 1608 | -14 |
| 1200 | 6025.19 | 5603.50 | 421.69 | 47 | 1650 | 0 | 0 | 1650 | 42 |
| 1300 | 6025.19 | 5603.50 | 421.69 | 47 | 1618 | 0 | 0 | 1618 | -32 |
| 1400 | 6025.17 | 5603.50 | 421.67 | 47 | 1630 | 0 | 0 | 1630 | 12 |
| 1500 | 6025.17 | 5603.50 | 421.67 | 47 | 1622 | 0 | 0 | 1622 | -8 |
| 1600 | 6025.17 | 5603.50 | 421.67 | 47 | 1614 | 0 | 0 | 1614 | -8 |
| 1700 | 6025.17 | 5603.50 | 421.67 | 47 | 1630 | 0 | 0 | 1630 | 16 |
| 1800 | 6025.17 | 5603.50 | 421.67 | 47 | 1612 | 0 | 0 | 1612 | -18 |
| 1900 | 6025.17 | 5603.50 | 421.67 | 47 | 1608 | 0 | 0 | 1608 | -4 |
| 2000 | 6025.17 | 5603.50 | 421.67 | 47 | 1604 | 0 | 0 | 1604 | -4 |
| 2100 | 6025.17 | 5603.47 | 421.70 | 46 | 1578 | 0 | 0 | 1578 | -26 |
| 2200 | 6025.17 | 5603.41 | 421.76 | 45 | 1286 | 0 | 0 | 1286 | -292 |
| 2300 | 6025.17 | 5602.80 | 422.37 | 27 | 994 | 0 | 0 | 994 | -292 |
| 2400 | 6025.17 | 5602.79 | 422.38 | 26 | 1004 | 0 | 0 | 1004 | 10 |
| Average | 6025.18 | 5603.26 | 421.92 | 40 | 1411 | 0 | 0 | 1411 | |
| Total | 956 | 33872 | 0 | 0 | 33872 | ||||
| Flaming Gorge | 5-Oct-13 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.15 | 5602.79 | 422.36 | 26 | 1002 | 0 | 0 | 1002 | -2 |
| 200 | 6025.17 | 5602.79 | 422.38 | 26 | 1004 | 0 | 0 | 1004 | 2 |
| 300 | 6025.19 | 5602.79 | 422.40 | 26 | 1006 | 0 | 0 | 1006 | 2 |
| 400 | 6025.15 | 5602.79 | 422.36 | 26 | 1008 | 0 | 0 | 1008 | 2 |
| 500 | 6025.15 | 5602.79 | 422.36 | 26 | 1004 | 0 | 0 | 1004 | -4 |
| 600 | 6025.17 | 5602.85 | 422.32 | 27 | 1304 | 0 | 0 | 1304 | 300 |
| 700 | 6025.15 | 5603.47 | 421.68 | 45 | 1558 | 0 | 0 | 1558 | 254 |
| 800 | 6025.17 | 5603.47 | 421.70 | 46 | 1582 | 0 | 0 | 1582 | 24 |
| 900 | 6025.17 | 5603.50 | 421.67 | 47 | 1598 | 0 | 0 | 1598 | 16 |
| 1000 | 6025.17 | 5603.50 | 421.67 | 47 | 1624 | 0 | 0 | 1624 | 26 |
| 1100 | 6025.15 | 5603.50 | 421.65 | 47 | 1606 | 0 | 0 | 1606 | -18 |
| 1200 | 6025.15 | 5603.50 | 421.65 | 47 | 1606 | 0 | 0 | 1606 | 0 |
| 1300 | 6025.15 | 5603.50 | 421.65 | 47 | 1626 | 0 | 0 | 1626 | 20 |
| 1400 | 6025.15 | 5603.50 | 421.65 | 47 | 1600 | 0 | 0 | 1600 | -26 |
| 1500 | 6025.13 | 5603.49 | 421.64 | 47 | 1606 | 0 | 0 | 1606 | 6 |
| 1600 | 6025.13 | 5603.49 | 421.64 | 47 | 1602 | 0 | 0 | 1602 | -4 |
| 1700 | 6025.15 | 5603.49 | 421.66 | 47 | 1590 | 0 | 0 | 1590 | -12 |
| 1800 | 6025.15 | 5603.50 | 421.65 | 47 | 1620 | 0 | 0 | 1620 | 30 |
| 1900 | 6025.13 | 5603.50 | 421.63 | 47 | 1610 | 0 | 0 | 1610 | -10 |
| 2000 | 6025.15 | 5603.49 | 421.66 | 47 | 1596 | 0 | 0 | 1596 | -14 |
| 2100 | 6025.15 | 5603.47 | 421.68 | 46 | 1580 | 0 | 0 | 1580 | -16 |
| 2200 | 6025.13 | 5603.41 | 421.72 | 45 | 1290 | 0 | 0 | 1290 | -290 |
| 2300 | 6025.15 | 5602.79 | 422.36 | 27 | 1004 | 0 | 0 | 1004 | -286 |
| 2400 | 6025.15 | 5602.79 | 422.36 | 26 | 1016 | 0 | 0 | 1016 | 12 |
| Average | 6025.15 | 5603.26 | 421.90 | 40 | 1402 | 0 | 0 | 1402 | |
| Total | 956 | 33642 | 0 | 0 | 33642 | ||||
| Flaming Gorge | 5-Oct-14 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.13 | 5602.79 | 422.34 | 26 | 1000 | 0 | 0 | 1000 | -16 |
| 200 | 6025.15 | 5602.79 | 422.36 | 26 | 996 | 0 | 0 | 996 | -4 |
| 300 | 6025.15 | 5602.79 | 422.36 | 26 | 998 | 0 | 0 | 998 | 2 |
| 400 | 6025.13 | 5602.79 | 422.34 | 26 | 1008 | 0 | 0 | 1008 | 10 |
| 500 | 6025.13 | 5602.79 | 422.34 | 26 | 1004 | 0 | 0 | 1004 | -4 |
| 600 | 6025.15 | 5602.85 | 422.30 | 27 | 1280 | 0 | 0 | 1280 | 276 |
| 700 | 6025.13 | 5603.46 | 421.67 | 45 | 1574 | 0 | 0 | 1574 | 294 |
| 800 | 6025.13 | 5603.47 | 421.66 | 46 | 1582 | 0 | 0 | 1582 | 8 |
| 900 | 6025.13 | 5603.50 | 421.63 | 47 | 1634 | 0 | 0 | 1634 | 52 |
| 1000 | 6025.13 | 5603.50 | 421.63 | 43 | 1628 | 0 | 0 | 1628 | -6 |
| 1100 | 6025.13 | 5603.50 | 421.63 | 47 | 1636 | 0 | 0 | 1636 | 8 |
| 1200 | 6025.13 | 5603.50 | 421.63 | 47 | 1600 | 0 | 0 | 1600 | -36 |
| 1300 | 6025.13 | 5603.50 | 421.63 | 47 | 1606 | 0 | 0 | 1606 | 6 |
| 1400 | 6025.13 | 5603.50 | 421.63 | 47 | 1602 | 0 | 0 | 1602 | -4 |
| 1500 | 6025.13 | 5603.50 | 421.63 | 47 | 1606 | 0 | 0 | 1606 | 4 |
| 1600 | 6025.11 | 5603.50 | 421.61 | 47 | 1616 | 0 | 0 | 1616 | 10 |
| 1700 | 6025.13 | 5603.50 | 421.63 | 47 | 1598 | 0 | 0 | 1598 | -18 |
| 1800 | 6025.13 | 5603.50 | 421.63 | 47 | 1618 | 0 | 0 | 1618 | 20 |
| 1900 | 6025.11 | 5603.50 | 421.61 | 47 | 1614 | 0 | 0 | 1614 | -4 |
| 2000 | 6025.11 | 5603.50 | 421.61 | 47 | 1598 | 0 | 0 | 1598 | -16 |
| 2100 | 6025.13 | 5603.46 | 421.67 | 46 | 1594 | 0 | 0 | 1594 | -4 |
| 2200 | 6025.11 | 5603.41 | 421.70 | 45 | 1292 | 0 | 0 | 1292 | -302 |
| 2300 | 6025.11 | 5602.80 | 422.31 | 27 | 1004 | 0 | 0 | 1004 | -288 |
| 2400 | 6025.11 | 5602.79 | 422.32 | 26 | 1006 | 0 | 0 | 1006 | 2 |
| Average | 6025.13 | 5603.26 | 421.87 | 40 | 1404 | 0 | 0 | 1404 | |
| Total | 952 | 33694 | 0 | 0 | 33694 | ||||
| Flaming Gorge | 5-Oct-15 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.11 | 5602.78 | 422.33 | 26 | 1008 | 0 | 0 | 1008 | 2 |
| 200 | 6025.11 | 5602.78 | 422.33 | 26 | 1008 | 0 | 0 | 1008 | 0 |
| 300 | 6025.11 | 5602.78 | 422.33 | 26 | 1004 | 0 | 0 | 1004 | -4 |
| 400 | 6025.11 | 5602.78 | 422.33 | 26 | 1008 | 0 | 0 | 1008 | 4 |
| 500 | 6025.11 | 5602.78 | 422.33 | 26 | 1000 | 0 | 0 | 1000 | -8 |
| 600 | 6025.09 | 5602.85 | 422.24 | 27 | 1288 | 0 | 0 | 1288 | 288 |
| 700 | 6025.11 | 5603.46 | 421.65 | 45 | 1618 | 0 | 0 | 1618 | 330 |
| 800 | 6025.11 | 5603.47 | 421.64 | 46 | 1582 | 0 | 0 | 1582 | -36 |
| 900 | 6025.11 | 5603.50 | 421.61 | 47 | 1598 | 0 | 0 | 1598 | 16 |
| 1000 | 6025.11 | 5603.50 | 421.61 | 47 | 1624 | 0 | 0 | 1624 | 26 |
| 1100 | 6025.09 | 5603.49 | 421.60 | 47 | 1626 | 0 | 0 | 1626 | 2 |
| 1200 | 6025.09 | 5603.49 | 421.60 | 47 | 1618 | 0 | 0 | 1618 | -8 |
| 1300 | 6025.07 | 5603.49 | 421.58 | 47 | 1620 | 0 | 0 | 1620 | 2 |
| 1400 | 6025.07 | 5603.49 | 421.58 | 47 | 1618 | 0 | 0 | 1618 | -2 |
| 1500 | 6025.05 | 5603.49 | 421.56 | 47 | 1626 | 0 | 0 | 1626 | 8 |
| 1600 | 6025.09 | 5603.49 | 421.60 | 47 | 1616 | 0 | 0 | 1616 | -10 |
| 1700 | 6025.07 | 5603.50 | 421.57 | 47 | 1608 | 0 | 0 | 1608 | -8 |
| 1800 | 6025.09 | 5603.50 | 421.59 | 47 | 1624 | 0 | 0 | 1624 | 16 |
| 1900 | 6025.11 | 5603.50 | 421.61 | 47 | 1620 | 0 | 0 | 1620 | -4 |
| 2000 | 6025.09 | 5603.50 | 421.59 | 47 | 1604 | 0 | 0 | 1604 | -16 |
| 2100 | 6025.07 | 5603.47 | 421.60 | 46 | 1578 | 0 | 0 | 1578 | -26 |
| 2200 | 6025.09 | 5603.41 | 421.68 | 45 | 1280 | 0 | 0 | 1280 | -298 |
| 2300 | 6025.11 | 5602.79 | 422.32 | 27 | 996 | 0 | 0 | 996 | -284 |
| 2400 | 6025.09 | 5602.79 | 422.30 | 26 | 1006 | 0 | 0 | 1006 | 10 |
| Average | 6025.09 | 5603.25 | 421.84 | 40 | 1407 | 0 | 0 | 1407 | |
| Total | 956 | 33778 | 0 | 0 | 33778 | ||||
| Flaming Gorge | 5-Oct-16 | ||||||||
| Hour | Elevation | Tail | Head | Generation | Power release | Spillway | Bypass | Total release | Ramping rate |
| (ft) | (ft) | (ft) | (MW) | (CFS) | (CFS) | (CFS) | (CFS) | (CFS) | |
| 100 | 6025.09 | 5602.79 | 422.30 | 26 | 1004 | 0 | 0 | 1004 | -2 |
| 200 | 6025.09 | 5602.79 | 422.30 | 26 | 1010 | 0 | 0 | 1010 | 6 |
| 300 | 6025.11 | 5602.79 | 422.32 | 26 | 1006 | 0 | 0 | 1006 | -4 |
| 400 | 6025.07 | 5602.79 | 422.28 | 26 | 998 | 0 | 0 | 998 | -8 |
| 500 | 6025.09 | 5602.79 | 422.30 | 26 | 1002 | 0 | 0 | 1002 | 4 |
| 600 | 6025.09 | 5602.85 | 422.24 | 27 | 1290 | 0 | 0 | 1290 | 288 |
| 700 | 6025.09 | 5603.46 | 421.63 | 45 | 1584 | 0 | 0 | 1584 | 294 |
| 800 | 6025.09 | 5603.47 | 421.62 | 46 | 1586 | 0 | 0 | 1586 | 2 |
| 900 | 6025.07 | 5603.50 | 421.57 | 47 | 1592 | 0 | 0 | 1592 | 6 |
| 1000 | 6025.09 | 5603.50 | 421.59 | 47 | 1598 | 0 | 0 | 1598 | 6 |
| 1100 | 6025.09 | 5603.50 | 421.59 | 47 | 1640 | 0 | 0 | 1640 | 42 |
| 1200 | 6025.11 | 5603.50 | 421.61 | 47 | 1616 | 0 | 0 | 1616 | -24 |
| 1300 | 6025.11 | 5603.50 | 421.61 | 47 | 1622 | 0 | 0 | 1622 | 6 |
| 1400 | 6025.05 | 5603.50 | 421.55 | 47 | 1630 | 0 | 0 | 1630 | 8 |
| 1500 | 6025.07 | 5603.50 | 421.57 | 47 | 1622 | 0 | 0 | 1622 | -8 |
| 1600 | 6025.09 | 5603.50 | 421.59 | 47 | 1616 | 0 | 0 | 1616 | -6 |
| 1700 | 6025.09 | 5603.50 | 421.59 | 47 | 1620 | 0 | 0 | 1620 | 4 |
| 1800 | 6025.05 | 5603.50 | 421.55 | 47 | 1608 | 0 | 0 | 1608 | -12 |
| 1900 | 6025.05 | 5603.50 | 421.55 | 47 | 1616 | 0 | 0 | 1616 | 8 |
| 2000 | 6025.09 | 5603.50 | 421.59 | 47 | 1600 | 0 | 0 | 1600 | -16 |
| 2100 | 6025.09 | 5603.46 | 421.63 | 46 | 1598 | 0 | 0 | 1598 | -2 |
| 2200 | 6025.07 | 5603.41 | 421.66 | 45 | 1294 | 0 | 0 | 1294 | -304 |
| 2300 | 6025.05 | 5602.79 | 422.26 | 27 | 1002 | 0 | 0 | 1002 | -292 |
| 2400 | 6025.09 | 5602.79 | 422.30 | 26 | 1008 | 0 | 0 | 1008 | 6 |
| Average | 6025.08 | 5603.26 | 421.82 | 40 | 1407 | 0 | 0 | 1407 | |
| Total | 956 | 33762 | 0 | 0 | 33762 |
Updated: 11/16/2005